Reference · 8-inch seawater membranes

FilmTec and Toray seawater membranes: data sheet values compared

This page puts the manufacturers' published values for 8-inch seawater RO elements side by side. Use it to see which FilmTec and Toray elements sit closest to each other before you ask for a quotation. All figures come from the current DuPont and Toray data sheets linked under each table.

Updated: October 2026

Request for quotation
Send the part number or a photo of the nameplate.
Reply within 4 business hours.
+ Add part number, quantity or a nameplate photo (optional)
JPG, PNG or PDF, max 8 MB

Quotations are free and carry no obligation. * required.
We use your details only to answer this request. Privacy.
sourcing@alisios.co ·

Test conditions

Both manufacturers test these elements at 32,000 mg/L NaCl, 800 psi (55 bar), 25 °C, 8% recovery. One condition differs: DuPont tests at pH 8 and Toray at pH 7. Toray states its boron rejection at pH 8. Flow and salt rejection can therefore be compared directly; boron rejection only approximately.

440 ft² (41 m²) elements

ElementPermeate flowStabilised salt rejectionMinimum salt rejectionBoron rejectionFeed spacer
FilmTec SW30XHR-4406,600 gpd (25 m³/d)99.82%99.70%93%28 mil
Toray TM820M-4407,700 gpd (29.2 m³/d)99.80%99.50%95% at pH 828 mil
FilmTec SW30HRLE-4408,000 gpd (30.2 m³/d)99.80%99.65%92%28 mil
FilmTec SW30XLE-4409,900 gpd (37.5 m³/d)99.80%99.60%91.5%28 mil
Toray TM820V-4409,900 gpd (37.5 m³/d)99.80%99.50%92% at pH 828 mil

Sources: DuPont — FilmTec SW30XHR-440 data sheet, DuPont — FilmTec SW30HRLE-440 data sheet (45-D00969), DuPont — FilmTec SW30XLE-440 data sheet (45-D00966), Toray — TM800M series data sheet (01-MB1-04), Toray — TM800V series data sheet (01-MB1-05).

400 ft² (37 m²) elements

ElementPermeate flowStabilised salt rejectionMinimum salt rejectionBoron rejectionFeed spacer
Toray TM820M-4007,000 gpd (26.5 m³/d)99.80%99.50%95% at pH 834 mil
FilmTec SW30HRLE-4007,500 gpd (28.4 m³/d)99.80%99.65%92%28 mil
Toray TM820V-4009,000 gpd (34.1 m³/d)99.80%99.50%92% at pH 834 mil

Sources: DuPont — FilmTec SW30HRLE-400 data sheet (45-D00967), Toray — TM800M series data sheet (01-MB1-04), Toray — TM800V series data sheet (01-MB1-05).

Closest elements by published flow

If the plant runsClosest element in the other brandDifference on the data sheet
FilmTec SW30XLE-440Toray TM820V-440Same flow (9,900 gpd). Minimum salt rejection 99.60% against 99.50%.
FilmTec SW30HRLE-440Toray TM820M-4408,000 gpd against 7,700 gpd. Minimum salt rejection 99.65% against 99.50%; Toray states higher boron rejection.
FilmTec SW30HRLE-400Toray TM820M-4007,500 gpd against 7,000 gpd. Feed spacer 28 mil against 34 mil.
FilmTec SW30XHR-440No TM800M or TM800V element at this flowThe SW30XHR-440 has the lowest flow and highest rejection in these tables (6,600 gpd, 99.82%).

Closest by data sheet is not the same as interchangeable. A change of model or brand alters the flow distribution and pressure in the vessel. Run a projection in the manufacturer's design software, or ask your process engineer, before ordering a different element.

FilmTec SEAMAXX-440 is tested differently

DuPont tests the SEAMAXX-440 at 600 psi (41 bar), not 800 psi: 9,050 gpd (34.2 m³/d) at 99.47% stabilised salt rejection. Its data sheet also gives expected values normalised to 800 psi: 17,000 gpd (64.4 m³/d) and 99.70%. Do not compare the 600 psi figures with the tables above.

Source: DuPont — FilmTec SEAMAXX-440 data sheet.

What is the same across these elements

  • All are 8-inch diameter, 40-inch long spiral-wound elements.
  • All have a maximum operating pressure of 1,200 psi (83 bar).
  • FilmTec models ending in i (for example SW30HRLE-440i) have iLEC interlocking end caps. A vessel loaded with iLEC elements needs iLEC replacements.

What we need to quote membranes

  1. The installed model exactly as written on the element label.
  2. Quantity and, for a partial replacement, the position of the elements in the vessel.
  3. If you want to change model or brand: feed water analysis and operating data.
  4. Delivery country and address.

Have the equipment nameplate to hand?

Send a photo or the part number. We check the model and reply within 4 business hours.

Frequently asked questions

What is the Toray equivalent of FilmTec SW30HRLE-440?

By published flow the closest Toray TM800 element is the TM820M-440: 7,700 gpd against 8,000 gpd at the same test pressure, salinity, temperature and recovery. The minimum salt rejection differs (99.50% against 99.65%), so confirm the change with a projection.

What is the Toray equivalent of FilmTec SW30XLE-440?

The Toray TM820V-440. Both data sheets state 9,900 gpd (37.5 m³/d) and 99.80% salt rejection at 800 psi, 32,000 mg/L NaCl, 25 °C and 8% recovery.

Can FilmTec and Toray data sheet values be compared directly?

Flow and salt rejection can, because both manufacturers test at 800 psi, 32,000 mg/L NaCl, 25 °C and 8% recovery. Boron rejection only approximately: DuPont tests at pH 8 and Toray tests at pH 7 while stating boron rejection at pH 8.

Why does SEAMAXX-440 show a lower rejection than other FilmTec seawater elements?

Because DuPont tests it at 600 psi instead of 800 psi. At 600 psi the data sheet states 99.47%; normalised to 800 psi it states 99.70%.

Can I replace a 440 ft² element with a 400 ft² element?

Physically both fit an 8-inch vessel, but the membrane area, flow and feed spacer differ, so the vessel hydraulics change. Treat it as a design change and run a projection first.