How to read an ATEX and IECEx marking on an instrument nameplate
Instruments and electrical equipment for explosive atmospheres carry an Ex marking. The marking states where the equipment may be installed and how it is protected. This page explains each part of a marking such as II 2 G Ex db IIC T6 Gb, so that a request for quotation can state the approval correctly.
WhatsApp: +34 655 099 909Updated: November 2026
Reply within 4 business hours.
Quotations are free and carry no obligation. * required.
We use your details only to answer this request. Privacy.
sourcing@alisios.co · WhatsApp
What is the difference between ATEX and IECEx?
ATEX is the European Union regime for equipment used in explosive atmospheres, set by Directive 2014/34/EU. Equipment sold in the EU for hazardous areas carries the CE mark, the hexagon Ex symbol and the ATEX group and category. IECEx is an international certification scheme based on the IEC 60079 series of standards. Many instruments carry both markings. The purchase specification of the plant states which one is required.
How is the marking II 2 G Ex db IIC T6 Gb read?
| Part | Meaning |
|---|---|
| II | Equipment group II: surface industries. Group I is mining. |
| 2 | Equipment category 2: high level of protection, suitable for zone 1. |
| G | Gas, vapour or mist atmosphere. D is used for dust. |
| Ex | Explosion-protected equipment. |
| db | Protection type: flameproof enclosure, protection level b. |
| IIC | Gas group IIC, which includes hydrogen and acetylene. |
| T6 | Temperature class: maximum surface temperature 85 °C. |
| Gb | Equipment protection level for gas, suitable for zone 1. |
The first three parts, II 2 G, are the ATEX group and category. The remainder is the marking defined by the IEC 60079 standards and appears in the same form on an IECEx certificate.
Which category and protection level suit which zone?
| Zone (gas) | Zone (dust) | ATEX category | Equipment protection level |
|---|---|---|---|
| 0 | 20 | 1 | Ga / Da |
| 1 | 21 | 2 | Gb / Db |
| 2 | 22 | 3 | Gc / Dc |
Equipment approved for a more demanding zone may also be used in a less demanding one.
What do the protection type letters mean?
| Code | Protection type |
|---|---|
| d | Flameproof enclosure |
| e | Increased safety |
| i (ia, ib, ic) | Intrinsic safety |
| p | Pressurised enclosure |
| m | Encapsulation |
| o | Liquid immersion |
| q | Powder filling |
| n | Type n, for zone 2 |
| t | Dust protection by enclosure |
What do the gas groups mean?
| Gas group | Representative gas |
|---|---|
| IIA | Propane |
| IIB | Ethylene |
| IIC | Hydrogen, acetylene |
Equipment marked IIC may be used where IIB or IIA is required. Equipment marked IIA may not be used where IIB or IIC is required.
What do the temperature classes mean?
| Class | Maximum surface temperature |
|---|---|
| T1 | 450 °C |
| T2 | 300 °C |
| T3 | 200 °C |
| T4 | 135 °C |
| T5 | 100 °C |
| T6 | 85 °C |
Why does the Ex marking matter in a request for quotation?
On most transmitters the approval is an option code inside the model code. The same transmitter with a flameproof approval and with an intrinsic-safety approval are two different part numbers. A replacement must carry the approval required by the area classification of the plant. Alisios quotes the approval stated in the request and does not substitute one protection type for another. Selecting equipment for a classified area is the responsibility of the plant's engineers.
Sources: Directive 2014/34/EU (ATEX), IECEx, the IEC system for certification to standards relating to equipment for use in explosive atmospheres.
Have the equipment nameplate to hand?
Send a photo or the part number. We check the model and reply within 4 business hours.
Related pages
What does Ex ia mean?
Ex ia is intrinsic safety with the highest level of protection. Energy in the circuit is limited so that it cannot ignite the atmosphere, and equipment marked ia with protection level Ga is suitable for zone 0.
What does T4 mean on an Ex nameplate?
T4 is a temperature class. The surface of the equipment will not exceed 135 °C, so it can be used where the ignition temperature of the gas is above that value.
Can IIB equipment be used in a IIC area?
No. Group IIC covers gases such as hydrogen and acetylene and needs equipment marked IIC. Equipment marked IIC can be used in IIB and IIA areas, but not the other way round.